Dental Center Fume Extraction | Dental Fume Removal
X

Dental Industry Fume Extraction

Dental Lab Applications Include the Following:

  • Dental Milling

  • Hand Working Processes

  • Crown / Bridge Framework

  • Monomers

  • 3D Print

  • CAD / CAM Manufacturing

Dental laboratory manufacturing processes cause dust particles and fumes to be released that can be harmful if inhaled. Our products eliminate the risks.

There is growing awareness of the potential Health & Safety issues regarding the presence of Zirconia dust and Monomer toxic fumes and vapours generated in dental laboratory manufacturing and hand finishing processes.

 

Although many of the dust particles are too small (< 5 microns) to be seen by the naked eye, just because they cannot be seen doesn’t mean the dangers for technicians don’t exist! In fact, these ultra-small particles can cause bronchial or lung damage.

 

Dental Aerosol Extraction

 

The DentalEX has been designed for dental aerosol extraction. This provides the dental industry with an extra layer of protection and reducing the dependence upon the mask as the last line of airborne defence. With its multi position arm and easy to use design, it slots straight into the dental work place. Purex units are designed and manufactured in the UK providing the quality and reliability that is required.

Coronavirus or Covid-19, has forced all industries to review their working practices. This is especially important in the dental industry. Covid-19 and other viruses are commonly transmitted between humans on the saliva. Many dental processes, such as the use of aerosols, can make for a much more concentrated burst of salvia than the average person would ever receive, potentially putting all those at risk of capturing any viruses present, whilst also infecting tools and equipment.

HEPA filtration has been proven for many years as an effective solution for filtering viruses. During a study conducted by the CDC. Titled ‘Methods for Surge Airborne Isolation within Healthcare Settings during Response to a Natural or Manmade Epidemic’, confirmed that HEPA filtration “provide better real-time source protection from infectious aerosol than that expected to result from an N95 respirator” (Mead et al.,2012)

Toxic Fumes

Monomers can potentially cause a wide range of adverse health effects, from irritation to the eyes, skin and mucous membranes, through to allergic dermatitis, asthma and disturbances to the central nervous system, liver toxicity and fertility disturbances. In particular, Methacrylate (MMA), a widely used monomer in dentistry, causes abnormalities or lesions in several organs.

Protecting Valuable Equipment

In addition to Health & Safety concerns, the prolonged release of dust and particulate can lead to a build up of material on valuable production equipment, leading to additional maintenance and potentially causing reliability issues.

 

All functions are fully automatic; all the user has to do is set the appropriate airflow on installation.
A dedicated control, monitoring and display system unique to Purex fume extractors.
Purex filter monitor units are in all our digital units; which is highly recommended for gases and chemicals emitted.
See all system features below:

  • Automatic Electronic Flow Control – Maintains A Constant Extraction Rate Even If The Filter Blocks
  • Adjustable Airflow
  • Clear And Informative Graphic Display
  • Gas And Particle Sensors On The Exhaust
  • Low Capital And Running Costs
  • Quick Change Patented Labyrinth Pre-Filters Deliver Longer Filter Life
  • Submicronic (Hepa) Filtration Removes 99.997% Of Particles Down To 0.3 Microns
  • Activated Carbon Filtrationremoves Harmful Gas
  • Interface With Other Equipment; i.e. Lasers
  • Simple To Install And Quiet In Operation
  • Easy To Relocate And Precision Made From Stainless Steel
  • High Performance Brushless Motors
  • Includes One 75Mm Ss Arm And One Clear Hood 420Mm X 320 mm
  • Additional Arm Item # 120197
  • Cabinetht. (Incl. Castors) 720 mm
  • Cabinet Depth 610 mm
  • Cabinet Width 445 mm
  • Cabinet Weight 50 Kg
  • Wattage 0.36kW; Frequency 50Hz/60Hz

Contact our team for more information about features and operation!

Purex Beauty Salon Fume Removal System

Custom Multi Station Systems Available 
Salon Fume Removal Systems

Brochure

 

 

650 Dental, Vacuum Control 120v.
3/8/2021
MPE-650-080470D
080470D-HOOD KIT, 080465D-HOOD KIT
.0021
68Kg 38x38x 30" Mach.+HoodKit, packed
150 lbs
$4,781.00
Jorlink USA, Inc,
3714 Alliance Dr., Suite 100
Greensboro, NC 27407
TEL: (336) 288-1613
eMail: sales@jorlink.com

M-F 9am-5pm EST 
Facebook Linkedin twitter Instagram YouTube