Item code: MPEF-113513
SKU: 113513
Filter Weight: 18Kg
Filter Dimensions: 365x365x260mm
Filter Type: Chemical Only
Carbon Volume: 0.0226m3
Activated Carbon Weight: 15Kg
113513 SDS
Machine Model: 650/200/400/200i/300i/400i/Alpha/IFume400i,Orange, Green, Red And Violet / DPX500
Export Notes: HTS Code: 8421.99.0180, Made in the UK-England
Freight Class: 125, NMFC# 069100-03
Welding Fumes
113513 as the best solution for welding fumes and solvent chemicals like thinners. (Lacquers: Acetone, Aliphatic Naphtha, Ethyl Acetate, Ethylbenzene, Methyl Alcohol, Methyl Ethyl Ketone, Toluene, and Xylene )
Most welding has whatever the metal byproducts are:
Aluminum, Antimony, Arsenic, Beryllium, Cadmium, Chromium, Cobalt, Copper, Iron, Lead, Manganese, Molybdenum, Nickel, Silver, Tin, Titanium, Vanadium, Zinc.
Plus Shielding Gas:
Argon, Helium, Nitrogen, Carbon Dioxide
Plus anything thermally generated by the process:
Nitric Oxide, Nitrogen Dioxide, Carbon Monoxide, Ozone, Phosgene, Hydrogen Fluoride, and Carbon Dioxide.
The Metals from the process would require a HEPA Filter.
There is not much we can do with the Shielding gas, these will pass through Carbon as do some of the thermally generated. If you had to use one,
I would say the 113668 is better than the 113513 because it has a HEPA…
Either way, you will still want a well-ventilated space and consult an industrial hygienist to be sure all health and safety concerns are being addressed.
Additionally if welding I would recommend a spark arrestor and metal pipe to the process.
Replacement Filter for Purex Purex Replacement Main Filter Adsorbs gases and vapors generated by ink jet printing and certain solvent applications. Must be specified for CIJ printing applications. |
|